Add-on modules • 7 – Pitney Bowes DI950 FastPac Inserter User Manual

Page 143

Advertising
background image

SV61311 Rev. E

7-17

Add-On Modules • 7

6. Verify the following:

• that there are sufficient funds for the job on the mailing system;
• that the MMI is working; and
• that the correct mode is set on the mailing system.

8. Press the

Start button on the inserting system.

NOTE: The IntelliLink

®

Control Center must be at the Main screen for the

interface to work. If the Control Center is not at the Main screen (for example,

in Sleep Mode), the “Postage Meter Unavailable” message will appear on the

inserter display screen.

The inserting system begins to assemble pieces of mail, which the mail-

ing system will then accept and process. The mailing system sends the

inserting system a message for each exiting piece of mail.

Clearing a Jam

If a jam occurs on the mailing system while processing mail with the MMI,

the “Remove Mailpiece” screen appears on the IntelliLink

®

Control Center.

Follow the steps below to clear the jam and resume processing mail.
1. Lift the mailing system cover(s) and remove the piece of mail from the

inside of the mailing system.

2. Select

Clear to bypass error on the control center.

3. Press

Start at the inserting system. Any mail remaining in the feeder is

printed, then the inserting system continues assembling and depositing

pieces of mail on the feeder.

1/8 - 1/4”

Clearance

between

envelope

and Side

Guide

Figure 7.16: Clearance Between Envelope and

Side Guide