8 • scanning – Pitney Bowes DI950 FastPac Inserter User Manual

Page 166

Advertising
background image

8-22

SV61311 Rev. E

8 • Scanning

Adjusting the

Scan Heads

for Picket

Orientation

Marks

To adjust the scan heads:
1. Fold one of the sheets to be scanned

in half vertically (side with mark facing

up.)

2. Draw two arrows, one at the top of the

mark, and one at the bottom of the

mark, pointing towards the top of the

sheet.

Vertical

fold

3. Fold the sheet horizontally, so the bar-

code appears on either side of the fold

line.

4. Open the Main Transport Deck Cover.

Use the ruler to measure the distance

from the center of the sheet (lined up

at 0 on the ruler) to the center of the

marks.

5. Refer to the loading instructions to

determine:
• The Scan Head location to be

used for this sheet (Left or Right)

• If the sheet will be loaded Top or

Bottom first.

6. Open the HCSF Tower cover.

TIPS:

• Remove the left Feeder Trays from the Feeder Tower to allow the

HCSF Tower cover to open freely.

• If you have two HCSFs on your system, the first HCSF Tower will pre-

vent the second tower (farthest) from opening fully. For best results,

be sure you have proper lighting when adjusting the Scan Head in the

second tower.

Horizontal

fold

Advertising