Chapter 4 Parameters|

4-82

Revision July 2008, EG03, SW V1.06

Content Address

Function

Fault code:

00: No error occurred
01: Over-current (oc)

02: Over-voltage (ov)

03: Overheat (oH)

04: Overload (oL)

05: Overload1 (oL1)

06: External fault (EF)
07: IGBT short circuit protection (occ)

08: CPU failure (cF3)

09: Hardware protection failure (HPF)

10: Current exceeds 2 times rated current during accel (ocA)

11: Current exceeds 2 times rated current during decel (ocd)
12: Current exceeds 2 times rated current during steady

state operation (ocn)

13: Ground Fault (GFF)

14: Low voltage (Lv)

15: CPU failure 1 (cF1)

16: CPU failure 2 (cF2)

17: Base Block (bb)

18: Overload (oL2)
19: Auto accel/decel failure (cFA)

20: Software protection enabled (codE)

21: EF1 Emergency stop

22: PHL (Phase-Loss)

23: Lc (Low-current)

24: FbL(Feedback Loss)

Status monitor

Read only

2100H

25: Reserved

26: Fan Power Fault (FANP)

27: Fan 1 Fault (FF1)

28: Fan 2 Fault (FF2)

29: Fan 3 Fault (FF3)

30: Fan 1, 2, 3 Fault (FF123)

31: Fan 1, 2 Fault (FF12)

32: Fan 1, 3 Fault (FF13)

33: Fan 2, 3 Fault (FF23)

34: Gate Drive Low Voltage Protect (Fv)