B.4 ac reactor, B.4.1 ac input reactor recommended value – Delta Electronics AC Motor Drive VFD-G User Manual
Page 169

Appendix B Accessories|
B-6
Revision July 2008, EG03, SW V1.06
B.4 AC Reactor
B.4.1 AC Input Reactor Recommended Value
460V, 50/60Hz, 3-Phase
Inductance (mh)
kW HP
Fundamental
Amps
Max. continuous
Amps
3% impedance
5% impedance
5.5 7.5
12
18
2.5
4.2
7.5 10
18
27
1.5
2.5
11 15
25
37.5
1.2
2
15 20
35
52.5
0.8
1.2
18.5 25
35
52.5
0.8
1.2
22 30
45
67.5
0.7
1.2
30 40
55
82.5
0.5
0.85
37 50
80
120
0.4
0.7
45 60
80
120
0.4
0.7
55
75
100 150 0.3 0.45
75 100
130
195
0.2
0.3
90 125
160
240
0.15
0.23
110 150
200
300
0.11
0.185
132 175
250
375
0.09
0.15
160 215
320
480
0.075
0.125
185 250
400
560
0.06
0.105
220 300
500
700
0.05
0.085
460V DC Choke
Input Voltage
kW
HP
DC Amps Inductance
(mh)
5.5 7.5
18
3.75
7.5 10
25
4.00
11 15
32
2.68
15 20
50
2.00
18.5kW~132kW(25HP~175HP): Built-in DC Reactor
160kW~220kW(215HP~300HP): Built-in AC Reactor