35~40:

Reserved

41: GFF hardware error (HPF1)

42: CC,OC hardware error (HPF2)

43: OC hardware error (HPF3)

44: OV hardware error (HPF4)

45: U-phase error (CF3.3)

46: V-phase error (CF3.4)

47: W-phase error (CF3.5)

48: OV or LV (CF3.6)

49: Isum error (CF3.7)

50: Temperature sensor error (CF3.8)

Status of AC drive

Status monitor

Read only

2101H

Bit 0-1

00: Run LED is off and stop led is on. (AC Drive

stopping)

01: Run LED is blink and stop led is on. (AC

Drive deceleration to stop)

10: Run LED is on and stop led is blink. (AC

Drive standby)

11: Run LED is on and stop led is off. (AC Drive

running)

Bit 2

1: Jog on.

Bit 3-4

00: Rev LED is off and FWD led is on. (Forward)
01: Rev LED is blink and FWD led is on.

(Reverse to Forward)

10: Rev LED is on and FWD led is blink.

(Forward to Reverse)

11: Rev LED is on and FWD led is off. (Reverse)

Bit 5-7

Reserved

Bit 8

Master frequency source via communication

interface

Bit 9

Master frequency source via analog

Bit 10

Running command via communication interface

Bit 11

Parameter locked

Bit 12-15

Reserved

2102H

Frequency command (F)

2103H

Output frequency (H)

2104H

Output current (AXXX.X)

2105H

DC-BUS Voltage U (XXX.X)

2106H

Output voltage E (XXX.X)

2107H

Power Factor (n)