PROXIMITY SENSOR
NOTE: A ground wire is not required.
1. Install the Dowel Pin (Item 4) into the Torque Limiter
(See Figure 7).
2. Using Cap Screws (Item 54), secure the Limit
Switch (Item 55) to the Mounting Bracket (Item 3)
(See Figure 7) using Mounting Plate (Item 57).
3. Using Cap Screws (Item 2), mount the Mounting
Bracket (Item 3) onto the Torque Limiter (See Figure
7).
4
54
55
3
2
57
FIGURE 7
AIR CONNECTIONS
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8373.1: 2001
Class 4.4.3 quality.
Figure 8
CAUTION
Do not use rigid pipe and tubing when making
air line connections. Torque on the air line
caused by bearing drag may be relieved by
resting the air line on a support parallel to the
torque limiter center-line. Align the air inlet
port to the six o'clock down position to allow
condensation in the air chamber to drain out
of the exhaust port.