Nexen RSTC1100 964528 User Manual

Page 9

Advertising
background image

9

FORM NO. L-21204-C-0705

CFL or Single Full Bridge Strain Gauge Load Cell

24 25 26 27 28 29 30 31 32 33 34

No. 2

Sensor

No. 1

Sensor

B

R

W

G

B

R

W

G

Dual MB

Single MB

24 25 26 27 28 29 30 31 32 33 34

Sensor

B

R

W

G

Cable

Shield

Add

Sensor 2

R

B

W

SW Sensor Colors

–Vex

+Vex

Vsig

24 25 26 27 28 29 30 31 32 33 34

Sensor 1

B

R

W

Cable

Shield

Add

Jumpers

SW Sensor Colors

–Vex

+Vex

Vsig

SW or Half Bridge Strain Guage Load Cell

24 25 26 27 28 29 30 31 32 33 34

Sensor

B

R

W

G

Cable

Shield

Add

CFL Sensor Colors

–Vex

+Vex

–Vsig

+Vsig

Figure 6

Control Input Signals

NOTE: To isolate the Control Input Signals, use a power
supply that is separate from the RSTC power supply.

Figure 8

Load Cell Connections

40 41 42 43 44 45 46

Cable Shields

+12 to + 24 VDC

DC Common

Run/Stop

Splice A

Splice B

32 33 34 35 36 37 38 39

1–5 kΩ

Potentiometer

NOTE: Potentiometer can be replaced with analog
voltage signal by connecting analog signal (0-12V
maximum) to terminal 37 and signal common to
terminal 38.

Figure 7

Remote Tension Setpoint