FIR II IP Core Parameters

3

2014.12.15

UG-01072

Subscribe

Send Feedback

You define a FIR filter by its coefficients. You specify the filter settings and coefficient options in the

parameter editor.
The FIR II IP core provides a default 37-tap coefficient set regardless of the configurations from filter

settings. The scaled value and fixed point value are recalculated based on the coefficient bit width setting.

The higher the coefficient bit width, the closer the fixed frequency response is to the intended original

frequency response with the expense of higher resource usage.
You can load the coefficients from a file. For example, you can create the coefficients in another applica‐

tion such as MATLAB or a user-created program, save the coefficients to a file, and import them into the

FIR II IP core.

Related Information

Loading Coefficients from a File

on page 3-3

Filter Specification Parameters

Table 3-1: Filter Specification Parameters

Parameter

Value

Description

Filter Settings
Filter Type

Single Rate
Decimation
Interpolation
Fractional Rate

Specifies the type of FIR filter.

Interpolation Factor 1 to 128

Specifies the number of extra points to generate

between the original samples.

Decimation Factor

1 to 128

Specifies the number of data points to remove

between the original samples.

Number of Channels 1–128

Specifies the number of unique input channels to

process.

Frequency Specification

©

2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134

Advertising