Error management registers settings, Error management registers settings –12 – Altera RapidIO II MegaCore Function User Manual

Page 42

Advertising
background image

3–12

Chapter 3: Parameter Settings

Error Management Registers Settings

RapidIO II MegaCore Function

August 2014

Altera Corporation

User Guide

■

If you do not instantiate the Error Management Extension registers (refer to

“Error

Management Registers Settings” on page 3–12

), this parameter determines the

value of the EF_PTR field of the LP-Serial Lane Extended Features Block Header
register at offset 0x200 (

Table 6–16 on page 6–21

).

■

If you instantiate the Error Management Extension registers in your RapidIO II IP
core variation, this parameter determines the value of the EF_PTR field of the Error
Management Extensions Block Header

register at offset 0x300 (

Table 6–66 on

page 6–43

).

1

This parameter does not affect the Assembly Information CAR. The
ExtendedFeaturesPtr

in the Assembly Information CAR is set to the value of 0x100,

which is the offset for the LP-Serial Extended Features block (refer to

Table 6–2 on

page 6–2

).

Error Management Registers Settings

The Error Management Registers tab lists a single parameter, Enable error
management extension registers

.

If you turn on Enable error management extension registers, your RapidIO II IP core
instantiates the Error Management Extensions register block defined in the RapidIO
Interconnect Specification Part 8: Error Management Extensions Specification
.

The RapidIO II IP core instantiates these registers at register block offset 0x300. If you
do not instantiate these registers, you can specify user-defined registers at offset
0x300.

The RapidIO II IP core Error Management registers are described in

“Error

Management Registers” on page 6–42

.