Applied Motion ST10-C-CE User Manual

Page 40

Advertising
background image

40

920-0025 Rev K

3/5/2015

CANopen User Manual

2A - ERROR_MEMORY_ALLOCATION_ERROR - Unable to allocate memory for objects.

2B - ERROR_GENERIC_ERROR - Generic error, test usage.

2C - ERROR_MAIN_TIMER_OVERFLOW - Mainline function exceeded maximum

execution time.

2D - ERROR_INTERNAL_STATE_APPL - Error in application software internal state.

2E - ERROR_2E_reserved - (reserved)

2F - ERROR_2F_reserved - (reserved)

0x2101 CAN node ID
The object allows the user to set the CAN Node ID of the Node, the change takes effect at

next power cycle.

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

UNSIGNED8

rw

no

no

3

This object can not be stored in non- volatile memory at this moment.

0x2102 CAN bit rate
The object allows the user to set the CAN bit rate of the Node, the change takes effect at

next power cycle.

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

UNSIGNED16

rw

no

no

0

This object can not be stored in non- volatile memory at this moment.

0x2103 SYNC counter
The object contains the counts of the SYNC message transmits/receives.

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

UNSIGNED16

rw

no

no

0

SYNC Counter is incremented each time, SYNC message is received or transmitted.
0x2104 SYNC time
Contains the time information between every adjacent two SYNC message.

Object Type

Data Type

Access Type

PDO Mapping

COS

Default value

Var

UNSIGNED16

ro

no

no

0

SYNC Time is incremented each timer period and reset to zero, each time SYNC is

received or transmitted.

Advertising