4�6�3�1�3� Scheduling time intervals in hours
If the
CirLAMP Manager has the
input and output module (
M8I8O Expansion module) the
work intervals can be programmed automatically from
Sunrise (Sunrise time).
Figure 20:Screen for scheduling time intervals in hours�
The parameters are:
Cnt: Node identifier.
inTime: Interval 1 activation time. This parameter cannot be modified; it coincides
with the
Sunrise value (Sunrise time).
power1: Power value in % during interval 1.
firstTime: Interval 2 activation time.
power2: Power value in % during interval 2.
secondTime: Interval 3 activation time.
power3: Power value in % during interval 3.
thirdTime: Interval 4 activation time.
power4: Power value in % during interval 4. Interval 4 will last until the node has
no power supply.
Click on the
Send button to send the data to the unit.
Read access user: The programming of intervals in hours cannot be modified.