CIRCUTOR CIRLAMP Series User Manual
Page 40

4�6�4�7� E07-L07, Alarm adjustment
Format of file
E07 (
):
<Order IdReq=”E07” IdPet=”2” Version=”3�1”>
<CirLamp Id=”CIR0000001”>
<E07 ActDate=”20121114165000000W”>
<Node
nodeId=”7000007”>
<Alarms blinkActive=”31” blinkTime=”301” blinkTimes=”3” blinkTo-
talTime=”7201” brokenActive=”31” brokenTime=”3601” capacitorReactive=”51” capac-
itorTime=”3601” powerLamp=”151” timeAlarm=”3663” percentageAlarm=”33” factor-
Power=”0�93”/>
</Node>
</E07>
</CirLamp>
</Order>
Figure 37: File E07�
Format of file
L07 (
):
<Report IdRpt=”L07” IdPet=”148” Version=”3�1”>
<CirLamp Id=”CIR0000000001”>
<L07
Fh=”20140310155534W”>
<Node Id=”1301250033” Fh=”20140310155518W” powerLamp=”151”
timeAlarm=”3661” percentageAlarm=”31” factorPower=”0�93” brokenTime=”0” blink-
Times=”3”/>
</L07>
</CirLamp>
</Report>
Figure 38: File L07�
Where:
Root element: <Report/Order>
<Report/Order> is the root element of the file. Its attributes indicate the data necessary to
process the file:
Table 34:File E07-L07, element <Report/Order>
Attribute
Description
IdRpt/IdReq
Report/order identifier.
IdPet
Single identifier for the order.
Version
Version identifier.
Container element: <CirLamp>
< CirLamp> is the container element for the report order:
Table 35:File E07-L07, element <CirLamp>
Attribute
Description
Id
CirLamp Manager identifier.
40
CirLAMP system
Instruction Manual