CIRCUTOR CIRLAMP Series User Manual
Page 33

4.6.4.2. E02-L02, Configuration of tasks
Format of file
E02 (
):
<Order IdRpt=”E02” IdPet=”0” Version=”3�1”>
<CirLamp Id=”CIR4600000001”>
<E02>
<TP TpTar=”1” TpHi=”20120915011000S” TpPer=”00000001000000” Tp-
Compl=”Y” TpPrio=”2”>
<TpPro TpReq=”L01” TpSend=”Y” TpStore=”Y”>
<TpAttr/>
</TpPro>
</TP>
</E02>
</CirLamp>
</Order>
Figure 28: File E02�
Format of file
L02 (
):
<Report IdRpt=”L02” IdPet=”0” Version=”3�1”>
<CirLamp Id=”CIR4600000001”>
<L02>
<TP TpTar=”1” TpHi=”20120915011000S” TpPer=”00000001000000” Tp-
Compl=”Y” TpPrio=”2”>
<TpPro TpReq=”L01” TpSend=”Y” TpStore=”Y”>
<TpAttr/>
</TpPro>
</TP>
</L02>
</CirLamp>
</Report>
Figure 29: File L02�
Where:
Root element: <Report/Order>
<Report/Order> is the root element of the file. Its attributes indicate the data necessary to
process the file:
Table 14:File E02-L02, element <Report/Order>
Attribute
Description
IdRpt/IdReq
Report/order identifier.
IdPet
Single identifier for the order.
Version
Version identifier.
Container element: <CirLamp>
< CirLamp> is the container element for the report order:
Table 15:File E02-L02, element <CirLamp>
Attribute
Description
Id
CirLamp Manager identifier.
33
Instruction Manual
CirLAMP system