CIRCUTOR DHB Series User Manual
Page 23

23
Table 4
dISP
Parameter
symbol
Description
Range of changes
d_P
Minimal position of the decimal point
when displaying the measured value
- display format. This parameter is not
taken into consideration during the
modes CountH and HoUr.
0.0000 – 0
00.000 – 1
000.00 – 2
0000.0 – 3
00000 –
4
CoLdo
Display colour, when the displayed
value is ower than CoLLo
rEd – red
grEEn – green
orAnG - orange
CoLbE
Display colour, when the displayed
value is higher than CoLLo and lower
than CoLHi
CoLuP
Display colour when the displayed value
is higher than CoLHi
CoLLo
Lower threshold of colour change
-19999..99999
CoLHi
Upper threshold of colour change
-19999..99999
ovrLo
Overflow of lower value of the measuring
range value or the programmed indica-
tion range is signaled on the display by
the
symbol.
-19999..99999
ovrHi
Overflow of upper value of the measur-
ing range value or the programmed
indication range is signaled on the
display by the
symbol.
-19999..99999