PRM-8 PROGRAMMING (CONTINUED)

Page 10

3.2 Update Parameter of Device Channel (96 hex)

Data Transmitted:

Byte# =

1

Valid Data Range =

0 or 1

Description =

0 = Enable front panel trim

pots for Page function

1 = Disable trim pots and use

PA-422 data for Page
function

Byte# =

2

Valid Data Range =

0-FF hex

Description =

Program source level
defined for all 8 channels.
(0 to -48dBu, -80dBu = off)

Byte# =

3

Valid Data Range =

0-FF hex

Description =

Program source fade in time
after page function is disabled.
(0 to 5 seconds)

FF hex = 5 seconds fade in time
0F hex = 2.5 sec. fade in time
00 hex = 0 seconds fade in time

Program source attenuation
levels can be calculated as
follows:
Attenuation (dBu) = 20 Log [
(Vin / 0.7747) (decimal value /
256)]

For example:
0F hex (15 decimal) = value
transmitted 0.7747v = Vin input
-24dBu = 20 Log[ (1) (15 /256) ]

Other example values for input
voltage of 0.7747v (Vin) are:
FF hex equals 0 dBu attenuation
0F hex equals -24 dBu attenuation
01 hex equals -48 dBu attenuation
00 hex equals -80 dBu attenuation

Data Received:

none

Byte# =

4

Valid Data Range =

0-FF hex

Description =

Program source fade out time
for enabled page function.
(0 to 5 seconds)
FF hex = 5 sec. fade out time
0F hex = 2.5 sec. fade out time
00 hex = 0 sec. fade out time