Diagnostics Display

OK OK ETHERNET

Total Devices xx Total Devices xx

If all devices attached are in there normal state (i.e. E-Stop

devices closed, Palm buttons OFF, Mute-out in guarded

condition, reset buttons in OFF) then the Diagnostics

Display will read “OK” and show the total number of

devices programmed into the HUB. If ETHERNET

appears on the display, this indicates that you have the

ETHERNET option and someone is currently accessing

that particular HUB device.

ESTOP-2W DEV#xx

Term# Ayy - Bzz

Indicates 2 wire device #xx has opened up. The Terminal

numbers that this device is connected to are shown on

the second line.

ESTOP-3W DEV#xx ESTOP-3W DEV#xx

Trm# Aww Byy Bzz Trm# Aww Ayy Bzz

Indicates 3 wire device #xx has opened up. The Terminal

numbers that this device is connected to are shown on

the second line.

ESTOP-4W Dev#xx

T# Avv-ww Byy-zz

Indicates a 4 wire device #xx has opened up. The Terminal

numbers that this device is connected to are shown on

the second line.

On Mat Dev#xx

T# Avv-ww Byy-zz

Indicates the 4 wire Mat(s) circuit is shorted (on mat)

and the Device number. The Terminal numbers that this

device is connected to are shown on the second line.

Mute ON RLY C Mute ON RLY D

Dev#xx T#Ayy-Bzz Dev#xx T#Ayy-Bzz

Indicates Mute-Out device for Relay C or D now active

(MUTED). The Device# and the Terminal numbers that

this device is connected to are shown on the second line.

Palms Active

Dev#xx T#Ayy-Bzz

Both Palm devices activated together within 1/4 second

of each other and held down. The Device number and

the Terminal numbers that this device is connected to are

shown on the second line.

Palm time out

Dev#xx T#Ayy-Bzz

Both Palms were NOT activated with 1/4sec of each

other. To clear this fault both palms must be released

(opened). The Device number and the Terminal num-

bers that this device is connected to are shown on the

second line.

RST pushd RLY C RST pushd RLY D

Dev#xx T#Ayy-Bzz Dev#xx T#Ayy-Bzz

Latching Relay Reset Button for Relay C or D was pushed

(cycled open/closed). To further reset relay outputs, you

must clear (open) the device back up). The Device number

and the Terminal numbers that this device is connected to

are shown on the second line.

CI active RLY C CI active RLY D

Dev#xx T#Ayy-Bzz Dev#xx T#Ayy-Bzz

Cincinnati Interface device for checking Relay C or D is

active (Relay output turned OFF). This Device must open

before the Relay output will attempt to turn back on. The

Device numberand the Terminal numbers that this device

is connected to are shown on the second line.

Limit SW DEV#xx

Term# Ayy - Bzz

Indicates 2 wire device #xx has activated. The Terminal

numbers that this device is connected to are shown on the

second line.