Device # fault

No such Device

Universal Safety Controller HUB was incorrectly

programmed or corrupted.

Mstr Mat Fault Slv Mat Fault

above limit above limit

Master or Slave Mat circuit detected an incorrect voltage

on the Mat terminals. Possibly incorrect wiring or jumper

configuration.

EDM K1K2 Fault EDM K1K2 Fault

On should be Off Off should be On

External Device Monitoring (external Relay checking)

found in wrong condition. Check wiring through external

relays (N.C. contacts).

Mute Fault Mute Fault

K1K2 Master 1K2 Slave

Master or Slave detected that the Mute-out Inputs (for

Channel C) were not in opposite states as required.

Check your Mute-Out signals and timing of them.

Mute Fault Mute Fault

K3K4 Master K3K4 Slave

Master or Slave detected that the Mute-out Inputs (for

Channel D) were not in opposite states as required.

Check your Mute-Out signals and timing of them.