IIC bus failure IIC bus failure

Master Slave

Master or Slave internal communications with external

devices lost. Could be fault circuits.

A/D Failure A/D Failure

Master Slave

Master or Slave analog voltage readings out of

specification.

Master Fault Slave Fault

Shut down all Shut down all

Master or Slave shut down for unknown reason.

K1 Relay K2 Relay

Not Energizing Not Energizing

K1 or K2 Relay Fault condition. Not turning ON when

asked to. This is the Safety Relay for Channel C. This

could indicate a faulty circuit. K1 is monitored by the

Slave, K2 is monitored by the Master.

K1 Relay K2 Relay

Stuck ON (fault) Stuck ON (fault)

K1 or K2 Relay Fault condition. Appears as ON, and will

not turn OFF. This is the Safety Relay for Channel C. This

could indicate a welded relay contact or faulty circuit or

fault relay. K1 is monitored by the Slave, K2 is monitored

by the Master.

K3 Relay K4 Relay

Not Energizing Not Energizing

K3 or K4 Relay Fault condition. Not turning ON when

asked to. This is the Safety Opto Relay for Channel D.

This could indicate a faulty circuit or the fuse is blown. K3

is monitored by the Slave, K4 is monitored by the Master.

K3 Relay K4 Relay

Stuck ON (fault) Stuck ON (fault)

K3 or K4 Relay Fault condition. Appears as ON, and will

not turn OFF (voltage appears on the D output). This is

the Safety Opto Relay for Channel D. This could indicate

a shorted Opto or faulty circuit . K3 is monitored by the

Slave, K4 is monitored by the Master.

Mstr On/Slv Off Slv On/Mstr Off

Dev#xx , Term#yy Dev#xx, Term#yy

A Device attached to the HUB has faulted out where the

Master indicated ON (B channel), but the Slave indicated

OFF (A channel), OR the Slave indicated ON (A channel),

but the Master indicated OFF (B channel). Check the

wiring of your Device# or the output from your device to

find the disparity between the A and B channels.

Mstr Off/Slv ON Slv Off/Mstr ON

Dev# ,Term# Dev# ,Term#

A Device attached to the HUB has faulted out where the

Master indicated OFF (B channel), but the Slave indicated

ON (A channel), OR the Slave indicated OFF (A channel),

but the Master indicated ON (B channel). Check the wiring

of your Device# or the output from your device to find the

disparity between the A and B channels.

False volt Fault

Dev# ,Term#

A 3 or 4 wire device# that requires a pulsed 24vdc output

from Channel A or B was checked as incorrect. This

maybe due to incorrect wiring or the device attached is

conflicting with the A or B output of the HUB.