Push push immediate – Zilog Z80380 User Manual
Page 170
Advertising

5-136
Z380
™
U
SER
'
S
M
ANUAL
DC-8297-03
Z
ILOG
PUSH
PUSH IMMEDIATE
PUSH src
src = IM
Operation:
if (LW) then begin
SP
←
SP - 4
(SP)
←
src(7-0)
(SP+1)
←
src(15-8)
(SP+2)
←
src(23-16)
(SP+3)
←
src(31-24)
end
else begin
SP
←
SP - 2
(SP)
←
src(7-0)
(SP+1)
←
src(15-8)
end
The Stack Pointer (SP) is decremented by two (by four in Long Word mode) and the source
is loaded into the memory locations addressed by the SP in ascending byte order in
ascending address memory locations.
Flags:
S:
Unaffected
Z:
Unaffected
H:
Unaffected
V:
Unaffected
N:
Unaffected
C:
Unaffected
Addressing
Execute
Mode
Syntax
Instruction Format
Time
Note
IM:
PUSH nn
11111101 11110101 -n(low)- -n(high)
3+w
I, L