Figure 6-12 – Adept i600 Cobra User Manual

Page 83

Advertising
background image

Installing the Robot Solenoid Kit

Adept Cobra i600/i800 Robot User’s Guide, Rev G

83

Figure 6-12. Connecting Spare Air Line to User Connector

13. Disconnect the tubing from the 6 mm User Air fitting shown in

Figure 6-12

. Fold

the tubing out of the way and restrain using cable ties.

14. Locate the spare air line contained in the tubing bundle inside the front end of the

cover. Remove the spare air line from the bundle.

15. Insert the spare air line into the back of the empty 6 mm User Air fitting.

NOTE: This 6 mm User Air connector and the corresponding 6 mm User
Air connector at the top of

Figure 6-2 on page 73

are not functional for

other uses after this modification.

16. Reinstall the Joint 1 cover, taking care to ensure that all tubing is inside the cover

and nothing gets crimped or pinched when pushing the cover into position.
Reinstall the screws to secure the cover. Tighten the screws to 1.6 N·m (14 in·lb).

17. Reinstall the outer link cover and tighten the screws to 1.6 N·m (14 in·lb) of

torque.

18. Connect the factory air supply to the modified 6 mm User Air connector.

19. Turn on system power and boot the system. The default values for the gripper

signals that activate the solenoids are 9 and 10. Once the system boot has
completed, at the MicroV

+

dot prompt, type in the following commands to

activate the solenoids one at a time.

.SIGNAL 9
.SIGNAL 10

WARNING:

The robot air pressure should be disconnected

until this test has been done to prevent unsecured
pneumatic lines from accidentally injuring personnel.

User Air fitting for
connecting spare line.
Remove factory
installed tubing first.

Tubing bundle
containing spare air
line

Joint 1 cover lifted to
access spare air line

Advertising