AMETEK ASD Series User Manual
Page 49

Sorensen ASD Series
Operation
M551177-01 Rev A
3-11
3.5.2 EXTERNAL VOLTAGE PROGRAMMING USING A
0-10 VDC VOLTAGE SOURCE
A DC voltage source for remote voltage programming is connected
between V_PROG (terminal 12 on digital option board, terminal 15 on SG
compatible option board, or terminal 9 on EtherCAT Option Board) and the
return terminal AGND (terminal 9 on digital option board, terminal 20 on
SG compatible option board, or terminal 5 on EtherCAT Option Board).
The voltage coefficient for 10V remote voltage programming is 10 volts =
100% of rated output voltage. See Figure 3-12 to Figure 3-14 for
connection requirements.
1
13
25
14
AGND
V_PROG
9
12
0-10V
Voltage source
+
-
Figure 3-12. Remote Voltage Programming Using 0-10 VDC Voltage Source (Digital
Option Board)
1
13
25
14
+
-
15
20
0-10V
Voltage source
V_PROG
AGND
Figure 3-13. Remote Voltage Programming Using 0-10 VDC Voltage Source (SG
compatible Option Board)