2.1.7 Unit Protection

Input Over current:

In-line fast acting fuses. Check fuse rating in Service and Maintenance section.
Ratings will depend on AC input configuration settings.

Circuit breaker for LV supply.

Input Over voltage:

Automatic shutdown.

Input Over voltage
Transients:

Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.

Output Over current:

Adjustable level constant current mode with programmable set point.

Output Short Circuit:

Peak and RMS current limit.

Over temperature:

Automatic shutdown.

2.2 Mechanical

Parameter

Specification

Dimensions:
(for each RS chassis)

Height:

74.5”

1892.3 mm

Width:

30.3”

769.6 mm

Depth:

38.3”

972.8 mm

Unit Weight:
(for each RS chassis)

Net:

2150 lbs / 975 Kg approximately

2475 lbs / 1123 Kg approximately including –AV option

Shipping:

2450 lbs / 1111 Kg

approximately

2775 lbs / 1258 Kg approximately including –AV option

Material:

Steel chassis with aluminum panels and covers.

Finish:

Light textured painted external surfaces.

Panels semi-gloss polyurethane color no. 26440 (medium gray)

Cooling:

Fan cooled with air intake on the front and exhaust to the rear.
Fans:

14 x 225CFM.

Air displacement

50 Cu Ft/sec. Max.

Internal Construction:

Modular sub assemblies.

Rear Panel
Connections:

(See section 3 for description of connections)

•

Cable entry and strain relieve for AC input wiring

•

Cable entry and strain relieve for output wiring

•

External sense terminal block (Remote voltage sense)

•

System interface (2x)

•

Clock and Lock BNC's (requires -LKM or -LKS options)

•

RS232, USB, GPIB, LAN (option)

•

Trigger In BNC

•

Trigger Out BNC

•

Function Strobe BNC

•

Output Status