WAVE GROUP

Sets the user defined waveform group that will be loaded at
power on. Available groups are 0, 1, 2 and 3. Each group can
contain up to 50 user-defined waveforms. A waveform group
can only be loaded at power up. To change groups, you must
change this field to the desired new group and cycle the power
to the AC source or issue a *RST command over one bus.

CLOCK MODE

Sets the clock source used at power up. Available settings are
Stand Alone (STAND), MASTER (-LKM clock and lock master),
and AUX (-LKS clock and lock auxiliary).

NO. OUTPUT

This field is always set to THREE can cannot be changed. It
reflects the three phase output configuration of the RS Sereis.

VOLT ALC

Determines ALC mode at power on. The ALC mode adjusts the
output voltage based on internal voltage measurement system
and provides enhanced output regulation and accuracy.
Available settings are ON, OFF or REG.