2.6.1 -HV Option Specifications
The -HV option provides an AC only output range of 0 to 400 Vac L-N. Specifications unique to
the -HV option are shown in the table below.
Output Parameter
RS90
RS180
RS270
RS360
RS450
RS540
Modes
Pi Controller
AC
Voltage:
Ranges (L-N):
0 -400 V
Resolution:
0.1 V
Accuracy:
± 0.25% of Full Scale / ± 1.0 Vac rms
Output Coupling
AC coupled
Power (total power for all phases, either range, at full scale voltage)
AC Mode
90 KVA
180 KVA
270 KVA
360 KVA
450 KVA
540 KVA
Current
Note: Current, maximum amps per phase available between 50 and 100 % of voltage range.
75 A
150 A
225 A
300 A
375 A
450 A
Peak Current
AC Mode
225 A
450 A
675 A
900 A
1125 A
1350 A
Frequency:
Range:
45 Hz – 819 Hz
with –LF option: 45 Hz – 500 Hz
with –HF option: 45 Hz – 905 Hz (see also –HF option specification.)