4.5 Standard Measurements
Standard measurements are always available through the MEAS key on the front panel. These
measurements are spread across two screens to enhance readability. Switching between these
screens can be done by successively pressing the MEAS button on the front panel. This will
cause the screen to cycle through all available measurement screens.
4.5.1
Standard Controller Measurements
For MX Series power sources with the
–1 standard controller, the following two measurement
screens are available:
Mode
AC
DC
MEASUREMENTS 1
VOLTAGE
AC rms voltage
DC Voltage
CURRENT
AC rms current
DC Current
FREQUENCY
Frequency
n/a
POWER
Real power
power
MEASUREMENTS 2
VA POWER
Apparent power
power
PEAK CURR
Highest AC current
found
Highest DC current
found
POWER FACT
Power factor
n/a
CREST FACT
Crest factor
n/a