ENTRY
DESCRIPTION
Output Calibration Screens
VOLT FS
Calibration coefficient for voltage output.
VOLT ZERO
Zero offset voltage calibration factor.
IMP REAL FS
Full scale resistive output impedance
calibration factor.
IMP REAC FS
Full scale inductive output impedance
calibration factor.
IMP REAL0in
Minimum resistive AC source output
impedance. The source has an output
impedance greater than zero. This value
determines the minimum resistive component
of the AC source output impedance.
IMP REAC0in
Minimum reactive AC source output
impedance. The source has an output
impedance greater than zero. This value
determines the minimum resistive component
of the AC source output impedance.
PHASE OFST
0.0 - 360.0
Phase offset calibration factor. Compensates
for phase shift caused by AC amplifier.