N table, N table 6-4, Table 6-4 – AMETEK MX15 Series User Manual
Page 129
Advertising

User Manual - Rev M
California Instruments
MX15
129
MX15
R resistive
Xl inductive
Controller (7003-718-5)
R121
R122
Table 6-4: Programmable Z adjustment pots
Definitions:
V
NL
= Measured RMS voltage under no load.
V
L
= Measured RMS voltage under load
I = Measured RMS current.
F = Source frequency (50 Hz).
= Phase angle shift between load and no load conditions. Record phase angle
from phase meter under NL and L condition and determine phase shift.
Formulas to calculate R and L component of output impedance:
R = ( V
NL
* cos(
) - V
L
) / I
X
L
= ( V
NL
* sin(
)) / I
L = X
L
/ (2 * Pi * F)
Table 6-5: Formulas to calculate R and L