AMETEK HPD Series User Manual
Page 16

Features and Specifications
Specifications
14
Operating Manual for GPIB for XT/HPD Series Power Supply
Table 1.2 Specifications for HPD 300 W Series Supply with GPIB Interface Installed
Models
15-20
30-10
60-5
Program Resolution
Voltage
Current
OVP
2.4mV
2.8mA
2.4mV
4.7mV
1.4mA
4.7mV
9.3mV
0.7mA
9.3mV
Program Accuracy
1
Voltage
Current
OVP
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model HPD 15-20 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 60mV ± 0.1% of the set voltage of
10 volts.
60mV
±0.1%
75mA
±0.12%
1.5V
70mV
±0.1%
50mA
±0.12%
3V
90mV
±0.12%
25mA
±0.1%
6V
Readback Resolution
Voltage
Current
2.4mV
2.8mA
4.7mV
1.4mA
9.3mV
1mA
Readback Accuracy
1
Voltage
Current
45mV
±0.3%
75mA
±0.12%
90mV
±0.3%
40mA
±0.12%
175mV
±0.3%
25mA
±0.1%