Installation and Configuration
Remote/Local Operation
22
Operating Manual for GPIB for XT/HPD Series Power Supply
Table 2.4 Remote Mode Power On Conditions
LOC
Command
The LOC command overrides the Remote/Local switch. Use LOC to enable or
disable one or all slave supplies to operate in local mode. See “Command Reference”
on page 40.
Condition
Default Settings
7.5-140 Model Example
Voltage
0 V
VSET 0
Current
0 A
ISET 0
Soft Voltage Limit
VMAX (see models)
VMAX 7.5
Soft Current Limit
IMAX (see models)
IMAX 140
OVP Trip Voltage
Model VMAX + 10%
OVSET 8.25
Delay
0.5 s
DLY 0.5S
Foldback Protection
OFF
FOLD OFF
Output
ON
OUT ON
Hold
OFF
HOLD OFF
Unmask
NONE
UNMASK NONE
Service Request Capability
OFF
SRQ OFF
AUXA
OFF
AUXA OFF
AUXB
OFF
AUXB OFF