Intelligent peripheral management controller – Artesyn ATCA-8330 Installation and Use (April 2015) User Manual
Page 158

Intelligent Peripheral Management Controller
ATCA-8330 Installation and Use (6806800S82B)
158
54
PWR
Entry
Status
OEM
0xD7
Sensor-specific
discrete
0x6F
0x0
Synchor Pwr Entr
Module:
[6] = VOUT_low
[5] = Hotswap
[4] = Holdup
[2] = Alarm
[1] = Enable_B
[0] Enable_A
Artesyn Pwr Entry
Module:
[7] = DIG_Fault
[6] = HUCapEngage
[5] =
Hotswap_Enable
[7:6] = Pwr
Entry
Module
0 = Ericson
1 = Artesyn
Artesyn Pwr
Entry
Module:
[2] =
DIG_EnableA
[1] =
DIG_EnableB
[0] =
Mcu_Fault
All other bits
are reserved
0x0: Pwr Entry
Module Status
Change detected
Ass
Auto
Table 7-2 ATCA-8330 Specific Sensors (continued)
Nr
Sensor
Name
Sensor Type
Event/
Reading
Type
Event Data
Byte 1
Event Data
Byte 2
Event Data
Byte 3
Event
Threshold/
Description
Ass-
ertion
Deass-
ertion
Rearm
Unr: Upper non-recoverable threshold
Unc: Upper non-critical threshold
Asrt: Assertion
Deass: Deassertion
Uc: Upper critical threshold
Lnr: Lower non-recoverable