For correctable memory error logging, there are two additional parameters to prevent the
flooding of the event logs. The parameters are:
Error Threshold - Correctable memory errors are logged when the threshold is reached.
The first correctable memory error is always logged.
Error Logging Limit - The number of logged correctable memory errors for a DIMM is
limited. If the last entry in the log is SMBIOS: 'Correctable memory log disabled' and IPMI:
Memory event 'Correctable ECC logging limit reached'. No further correctable errors are
logged for this DIMM.
Table 4-16 Logged Error Events
Error
SMIBIOS
IPMI
Correctable:
- Correctable ECC Memory Error
Single-bit ECC memory error
Sensor: Memory, Offset 00h
Correctable:
- Memory Error Limit Reached
- Correctable ECC logging limit reached
Correctable memory log disabled
Sensor: Memory, Offset 05h
Uncorrectable:
- Uncorrectable ECC Memory Error
Multi-bit ECC memory error
Sensor: Memory, Offset 01h
PCI PERR
PCI Parity Error
Sensor: Critical Interrupt,
Offset 04h PCI PERR
PCI SERR
PCI System Error
Sensor: Critical Interrupt,
Offset 05h PCI SERR