5 dxe beep codes, Table 5-46, Dxe beep codes – Artesyn COMX-CORE Series Installation and Use (August 2014) User Manual
Page 113: Bios

BIOS
COMX-CORE Series Installation and Use (6806800K11F)
113
5.7.2.5
DXE Beep Codes
0xB5
PCI bus hot plug
0xB6
Clean-up of NVRAM
0xB7
Configuration Reset (reset of NVRAM settings)
0xB8 - 0xBF
Reserved for future AMI codes
0xC0 - 0xCF
OEM BDS initialization codes
DXE Error Codes
0xD0
CPU initialization error
0xD1
North Bridge initialization error
0xD2
South Bridge initialization error
0xD3
Some of the Architectural Protocols are not available
0xD4
PCI resource allocation error. Out of Resources
0xD5
No Space for Legacy Option ROM
0xD6
No Console Output Devices are found
0xD7
No Console Input Devices are found
0xD8
Invalid password
0xD9
Error loading Boot Option (LoadImage returned error)
0xDA
Boot Option is failed (StartImage returned error)
0xDB
Flash update is failed
0xDC
Reset protocol is not available
Table 5-45 DXE Status Codes (continued)
Status Code
Description
Table 5-46 DXE Beep Codes
# of Beeps
Description
4
Some of the Architectural Protocols are not available
5