3.4

Restart after Emergency-Stop

ATTENTION

Before you restart the machine you should remove the reason for the
Emergency-Stop. Contact the responsible technician in any doubtful case.
The machine may only be restarted after the reason for the Emergency-Stop
has been removed.

Switch on the machine using the main switch. The current program number
will be imaged in the display of the operation device. The machine is ready to
use.

3.5

Adjust compressed air pressure

The machine needs an air pressure between 5 and 6 bar. This is adjusted at
the air supply unit:

1 Control to adjust the air pressure

2 Air connecting hose

3 Pressure gauge

4 Collector for condensing water

5 Release valve for condensed water

Check the air pressure at the pressure gauge (3). If the indicated value
differs from 6 bar, adjust the pressure by turning the black control (1).

4

Operation of the sewing head

The operation of the sewing head is explained in the separate manual of the
sewing head, which is part of the machine’s documentation.

Please obtain all rules and regulations.