Donut Robot Mark VI TS

THE ELEMENT WILL NOT HEAT, AND THE CONVEYOR WILL NOT RUN.

Possible Causes

What To Do

The power cord is not plugged in, or the outlet
has no power.

Connect the machine to a good power source.

WARNING

To avoid being burned or electrocuted, before
doing any of the following, turn off the machine,
allow the shortening to cool, and disconnect the
machine from the power source.

The power cord is defective.

Replace the power cord.

The transformer is defective.

Replace the transformer.

The connections to the transformer are bad.

Rewire the connections to the transformer.

THE ELEMENT WILL NOT HEAT, BUT THE CONVEYOR RUNS.

Possible Causes

What To Do

The high temperature limit control switch has
been tripped.

Push the red reset button on the back panel of the
heater head.

The thermostat has been calibrated incorrectly.

Recalibrate the thermostat.

WARNING

To avoid being burned or electrocuted, before
doing any of the following, turn off the machine,
allow the shortening to cool, and disconnect the
machine from the power source.

The high temperature limit control is defective.

Replace the high temperature limit control.

The thermostat is defective.

Replace the thermostat.

The contactor for the transistor is defective.

Replace the contactor.

The connections to the contactor are bad.

Rewire the connections to the contactor.