P25 RADIO SYSTEMS | TRAINING GUIDE

Chapter 6: P25 Trunking Page 81

The Trunking Signaling block contains 10 octets of address and control information,
followed by 2 octets of CRC.

Following is the general description of the fi elds of this TSBK:

Last Block fl ag (LB)

%0

more TSBKs to follow in this packet

%1

this is the last TSBK in the packet

Protected trunking block fl ag (P)

%0

non-protected packet mode

%1

protected packet mode

Opcode

The Opcode defi nes the specifi c type of message the TSBK contains in the Arguments fi eld (eg. Group
call, unit to unit call, status message, registration, etc.).

Manufacturer’s ID (MFID)

The MFID standard value of $00 is used unless the TSBK contains a nonstandard (manufacturer
specifi c) control channel message. $01 is reserved.

Arguments

The Arguments contains the information of the TSBK. The specifi c type of information is defi ned by
the Opcode.

CRC

The CRC is the CRC parity check for the TSBK.