Trunking control message – Codan Radio P25 Training Guide User Manual

Page 91

Advertising
background image

P25 RADIO SYSTEMS | TRAINING GUIDE

Chapter 6: P25 Trunking Page 83

Figure 6-7: Multiple Block Trunking (MBT)

Optionally

Protected

Alternate Multi Block Trunking Header

0

A/N

Bit 7

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 0

Bit 1

Octet 0

Octet 6

Octet 5

Octet 4

Octet 3

Octet 2

Octet 1

Octet 9

Octet 8

Octet 7

Octet 11

Octet 10

Blocks to follow

MFID

Logical Link ID

SAP Identifier

1

0

I/O

1

1

1

1

1

1

0

0

Opcode

Defined by Trunking Messages

Header CRC

Defined by Trunking Messages

Multi-Block Trunking Packet

0

A/N

Bit 7

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 0

Bit 1

Octet 0

Octet 6

Octet 5

Octet 4

Octet 3

Octet 2

Octet 1

Octet 9

Octet 8

Octet 7

Octet 11

Octet 10

Blocks to follow

MFID

Logical Link ID

SAP Identifier

1

0

I/O

1

1

0

1

1

1

0

0

Pad Octet Count

Reserved

Header CRC

Data Header Offset

0

0

0

Unconfirmed Data Header

Bit 7

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 0

Bit 1

Octet 0

Octet 6

Octet 5

Octet 4

Octet 3

Octet 2

Octet 1

Octet 9

Octet 8

Octet 7

Octet 11

Octet 10

Trunking Control Message

Data Block

Bit 7

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 0

Bit 1

Octet 0

Octet 6

Octet 5

Octet 4

Octet 3

Octet 2

Octet 1

Octet 9

Octet 8

Octet 7

Octet 11

Octet 10

Trunking Control Message

Packet CRC (Last Data Block Only)

Last Data Block

Advertising