Comtech EF Data SMS-301 User Manual
Page 31

SMS-301 Redundancy Switch
Installation
Rev. 3
2–9
2.3.2.4
Data I/O (J1, J2, J3) 37-Pin (PL/6201-1)
Note: For EIA-422/LVDS DVB (Serial or Parallel) Interface applications.
The 37–pin D subminiature connector has the pin assignments shown in Table 2-7.
Table 2-7. Connector Assignments, 37-Pin
Pin #
Signal Function/Name
Comment
1
Signal GND
Mod/Demod
2
REF CLK/GND B
REF CLK
3
MF
Mod Fault
4
NC
No Connection
5
NC
No Connection
6
D0B
Data
7
D1 B
Data
8
D2 B
Data
9
D3 B
Data
10
D4 B
Data
11
D5 B
Data
12
D6 B
Data
13
D7 B
Data
14
Valid B
Valid
15
SYNC B
SYNC
16
NC
No Connection
17
NC
No Connection
18
NC
No Connection
19
CLK A
Clock
20
NC
No Connection
21
REF CLK/GND A
REF CLK
22
DF
Demod Fault
23
NC
No Connection
24
NC
No Connection
25
D0 A
Data
26
D1 A
Data
27
D2 A
Data
28
D3 A
Data
29
D4 A
Data
30
D5 A
Data
31
D6 A
Data
32
D7 A
Data
33
Valid A
Valid
34
SYNC A
SYNC
35
NC
No Connection
36
NC
No Connection
37
CLK B
Clock