Comtech EF Data SMS-301 User Manual
Page 94

Remote Control Operation
SMS-301 Redundancy Switch
A-12
Rev. 3
Equipment
Type
Command:
Response:
<add/ET_'cr'
>add/ET_tttttttt_xxx.yyy.zzz'cr''lf']
Where:
tttttttt = Equipment Type.
xxx.yyy.zzz = Software Version number (0.0.0 to
999.999.999).
This command returns the equipment type and the
software version of the addressed device.
Monitor &
Control
Firmware
Information
Command:
Response:
<add/MCFI_'cr'
>add/MCFI_'cr'
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']
Where:
xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
Boot M&C
Firmware
Information
Command:
Response:
<add/BFI_'cr'
>add/BFI_'cr'
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']
Where:
xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).