SMS-301 Redundancy Switch
Remote Control Operation
Rev. 3
A-5
A.3 Configuration
Commands/Responses
Operational
Mode
Command:
Response:
Status:
Response:
<add/MODE_xxxxxx'cr'
>add/MODE_xxxxxx'cr''lf']
<add/MODE_'cr'
>add/MODE_xxxxxx'cr''lf']
Where: xxxxxx = AUTO or MANUAL.
This command selects the mode of operation for the SMS301.
Notes:
1. If AUTO is selected, the Monitor and Control in the
SMS301 controls all switching decisions.
2. If MANUAL is selected, the operator controls all
switching decisions via the next 3 following commands.
Set Online
Modulator
(Indepen-
dent
Switching)
Command:
Response:
Status:
Response:
<add/MOL_x'cr'
(See Note)
>add/MOL_x'cr''lf']
<add/MOL_'cr'
>add/MOL_x'cr''lf]
Where: x = A or B (Modulator Online number).
This command puts the specified modulator online.
Note: Manual Mode Only.
Set Online
Demod
(Indepen-
dent
Switching)
Command:
Response:
Status:
Response:
<add/DOL_x'cr'
(See Note)
>add/DOL_x'cr''lf']
<add/DOL_'cr'
>add/DOL_x'cr''lf]
Where: x = A or B (Demodulator Online number).
This command puts the specified demodulator online.
Note: Manual Mode Only.
Set Online
Modem
(Dependent
Switching)
Command:
Response:
Status:
Response:
<add/MOL_x'cr'
(See Note)
>add/MOL_x'cr''lf']
<add/MOL_'cr'
>add/MOL_x'cr''lf]
Where: x = A or B (Modem Online number).
This command puts the specified modem online.
Note: Manual Mode Only.
Modulator's
Active
(Enable)
Command:
Response:
Status:
Response:
<add/MA_yyy'cr'
(See Note)
>add/MA_yyy'cr''lf']
<add/MA_'cr'
>add/MA_yyy'cr''lf']
Where: yyy = YES or NO.
Note: Manual Mode Only.
Demod
Active
(Enable)
Command:
Response:
Status:
Response:
<add/DA_yyy'cr'
(See Note)
>add/DA_yyy'cr''lf']
<add/DA_'cr'
>add/DA_yyy'cr''lf']
Where: yyy = YES or NO.
Note: Manual Mode Only.
Switching
Mode
Selection
Command:
Response:
Status:
Response:
<add/SM_yyy'cr'
(See Note)
>add/SM_yyy'cr''lf']
<add/SM_'cr'
>add/SM_yyy'cr''lf']
Where: yyy = IND (Independent) or DEP (Dependent).
Note: Manual Mode Only.
Modem
Online
Delay
(Dependent
Switching)
Command:
Response:
Status:
Response:
<add/MD_yyy.y'cr'
>add/MD_yyy.y'cr''lf]
<add/MD_'cr'
>add/MD_yyy.y'cr''lf]
Where: yyy.y = 0.0 to 127.0 seconds (in .5 second
increments).
Modulator
Online
Delay
(Indepen-
dent
Switching)
Command:
Response:
Status:
Response:
<add/MD_yyy.y'cr'
>add/MD_yyy.y'cr''lf]
<add/MD_'cr'
>add/MD_yyy.y'cr''lf]
Where: yyy.y = 0.0 to 127.0 seconds (in .5 second
increments).