4 initial configuration – Comtech EF Data CME-5200 Manual User Manual

Page 19

Advertising
background image

CME-5200 Digicast Media Router ASI Receiver

Revision A

Installation & Initial Configuration MN/MRASIRCDC.IOM

2.4 Initial

Configuration

The initial configuration involves setting up the IP parameters via the terminal cable.
Once the IP parameters have been configured, the terminal cable can be removed. The
terminal cable should be stored in a known location, since it may be needed in the future.

To configure the IP parameters:

Step

Procedure

1

Using a terminal emulator on a PC such as HyperTerminal™ or
TeraTerm™, set up the communication port as follows:

• 38,400 BAUD

• 8 Data Bits

• 1 Stop Bit

• No Parity

• No Flow Control

2 Press

the <ENTER> key on the PC – the ASI-R’s menu should be

displayed.

3 Press

N” for Network Menu.

4 Press

I” for the IP Address, Enter the IP Address and press <ENTER>.

5 Press

M” for the Subnet Mask. Enter the Subnet Mask and press

<ENTER>.

6 Press

G” for the Default Gateway IP Address. Enter the Default

Gateway Address and press <ENTER>.

7 Press

S” to save the parameters.

8 Press

Y” to confirm the saving of parameters.

9 Press

X” to exit to the main menu.

10 Press

P” to configure the PIDs. Enter a valid number of PIDs and press

<ENTER>.

11 Press

Y” to confirm the saving of parameters.

12 Press

X” to exit to the main menu.

At this point, the unit has been configured for full operation and the terminal cable may
be removed. The ASI cable may now be safely attached to the

ASI IN

(input) port. For

continued operation the unit may be managed via the Terminal Interface; however, it is
recommended to use the Web Interface for ease of management.

2-3

Advertising