Commonequipstatus, A.7.101 commonequipstatus, A.7.101 – Comtech EF Data CiM-25/9000 User Manual

Page 125

Advertising
background image

CiM-25/9000 IP Enabled M&C

Rev. 1

SNMP Interface

CD/CIM259000.IOM

107

A.7.101

COMMON

E

QUIP

S

TATUS

Name

commonEquipStatus

OID

1.3.6.1.4.1.6247.16.1.6.13

Full path

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(624
7).sdm9000(16).sdm9000Objects(1).statusParameters(6).commonE
quipStatus(13)

Module

SDM9000

Parent

statusParameters

Prev sibling

rxInterfaceStatus

Next sibling

backwardAlarmStatus

Type

OBJECT-TYPE

Numerical syntax

SNMP_SYNTAX_INT

Base syntax

INTEGER

Composed syntax

INTEGER

Status

current

Max-access

read-only

Size list

1

0..127

Description

Common Equipment Fault Status. (CES_)

Bit 0 = M&C Module (0=OK, 1=FLT)

Bit 1 = Data Interface Module (0=OK, 1=FLT)

Bit 2 = Battery / Clock (0=OK, 1=FLT)

Bit 3 = +5V Power Supply (0=OK, 1=FLT)

Bit 4 = -5V Power Supply (0=OK, 1=FLT)

Bit 5 = +12V Power Supply (0=OK, 1=FLT)

Bit 6 = -12V Power Supply (0=OK, 1=FLT)