3.6 M
AINTENANCE
I
NTERFACE
The CiM-25 has been designed to support a means of allowing a customer to reset the
unit back to the factory default settings via the RS-232 interface. To accomplish this the
user must do the following:
1.
Disconnect the CiM-25 form both the interfacing equipment and the Ethernet Network.
2.
Connect the CiM-25 to the serial port of a PC using a cable defined below (null cable):
a.
CiM-25 pin 2 to PC pin 3.
b.
CiM-25 pin 3 to PC pin 2.
c.
CiM-25 pin 5 to PC pin 5.
3.
Power the CiM-25/9000 using the Power Jack connector and a external 5 Vdc power
supply.
4.
Using a Serial Communication application such as Terminal, ProComm, etc., configure the
PC’s serial port to 19200 baud, 8-N-1
5.
Enter the following command:
Command:
<0/RST’cr’>