Chapter 2 Hardware Installation

Chapter 2

Backlight Power Select

Panel Power Select

1-2 On: +12V

3-4 On:+5V

5-6 On: +3.3V

(default)

2-3 On: +5V

1-2 On: +3.3V (default)

JP8 is used to select the power supplied with the LCD panel.

Important:

Before powering-on the system, make sure that the power settings of JP8 match the

LCD panel’s specification. Selecting the incorrect voltage will seriously damage the

LCD panel.

JP7 is used to select the power level of backlight control: +3.3V (default) or +5V.

Important:

Before powering-on the system, make sure that the power settings of JP7 match the

power specification of backlight control. Selecting the incorrect voltage will seriously

damage the backlight.

6

4

2

5

3

1

JP8

6

4

2

5

3

1

6

4

2

5

3

1

JP7

3

1

2

3

1

2