background image

18 DR

®

COMMERCIAL LEAF and LAWN VACUUM

Blower Exit Elbow Assembly Installation

The following procedure includes the steps necessary for
installing the Blower Exit Elbow Assembly on the DR
LEAF and LAWN VACUUM.















Connecting the Collector Box Inlet Hose to the
Blower Exit Elbow Assembly

The following procedure includes the steps necessary for
connecting the Collector Box Inlet Hose to the Blower
Exit Elbow Assembly on the DR LEAF and LAWN
VACUUM.

Blower Exit Elbow

Pull and Hook
Flexible Latches

Collector Box Hose

Hook here

Figure 15

Figure 14

Collector Box
Hose

Blower Exit Elbow
Assembly

Wing Screw
4 places

Lanyard

1. Install the Blower Exit Elbow Assembly on top of

the Blower Housing with the elbow pointing
toward the Collector Box (Figure 14).

2. Align the hood of the Blower Exit Elbow

Assembly to ensure that the Safety Interlock
Switch is depressed (Figure 14), verify the
position of the Lanyard as shown, and then
install a Lock Washer and Flat Washer over each
of the four (4) 5/16" x 1/2" Wing Screws and
hand tighten them to the Blower Housing
(Figure 14).

Tip: Start all four (4) Wing Screws before tightening

them securely.

1. Connect the Hose from the Collector Box to the

Blower Exit Elbow Assembly by aligning the two
(2) Flexible Latches (Figure 15) and slipping the
Hoses together.

2. Pull and hook the two (2) Flexible Latches into

place (Figure 15) to secure the Hoses.

Blower
Housing

Switch Depressed

Elbow