For 460 VAC Operation

Jump pin 4 to pin 5. Power is applied to pins 1 and 8 via AC input connector C3.

For 480 VAC Operation

Jump pin 4 to pin 5 and pin 8 to pin 9. Power is applied to pins 1 and 10 via AC input connector C3.

Figure 8 120V/208V/230V Quad Amplifier Transformer T201 Schematic Diagram

Figure 9 380V/460V/480V Quad Amplifier Transformer T201 Schematic Diagram