Delta Tau 3Ax-602646-xUxx User Manual

Page 26

Advertising
background image

Quad Amp Hardware Reference Manual

Installation

22

1 2

3

3 2

1

Figure 10 Logic I/O Board Jumper and LED Locations

Name Position

Description

Default

E1-E4 IN

Shield

To

Local Ground

Open

OUT

E7 IN

Do

Not

Use

Open

OUT

E8 IN

Enable

Shunt

Transistor In Module

Open

OUT

E9 IN

Enable

Shunt

Transistor In Module

Open

OUT

E10 IN

Do

Not

Use

Open

OUT

E28 IN

Do

Not

Use

Open

OUT

E29 IN

Do

Not

Use

Open

OUT

E30 IN

Do

Not

Use

Open

OUT

LED Symbol

Description

D5

+ 15 V

On when + 15VDC logic power is present

D6

+ 5 V

On when + 5 VDC logic power is present

D7

- 15 V

On when - 15 VDC logic power is present

D14

AXIS 1 FLT

On when Axis #1 faulted

D15

AXIS 2 FLT

On when Axis #2 faulted

D16

AXIS 3 FLT

On when Axis #3 faulted

D17

AXIS 4 FLT

On when Axis #4 faulted

D18

AXIS 1 EN

On when Axis #1 is enabled

D19

AXIS 2 EN

On when Axis #2 is enabled

D20

AXIS 3 EN

On when Axis #3 is enabled

D21

AXIS 4 EN

On when Axis #4 is enabled

D22

PWR GOOD

On when all logic powers are at the proper level

D50

GOT ENABLE

On when any AXIS ENABLE signal is received at the Logic PCB

D55

VNI

On when + 15 VDC logic power for output IGBTs is present