Output specifications for 380/460 vac amplifier, Continuous current (rms), Continuous 2 min hp(200%) – Delta Tau 3Ax-602646-xUxx User Manual

Page 9: Peak 2 sec hp(300%), Peak 2 sec current, Pwm dead time, Continuous 2 min hp (200%), Peak 2 sec hp (300%), Dead-time

Advertising
background image

Quad Amp Hardware Reference Manual

Introduction

5

Opt 5

Opt 6

Opt 7

Opt 8

Opt 9 Opt 10 Opt 11 Opt 12 Opt 13 Opt 14

Continuous
HP(100%)

0.75 HP

0.56 kW

1.5 HP

1.1 kW

2 HP

1.5 kW

3 HP

2.2 kW

5 HP

3.7 kW

7.5 HP

5.6 kW

10 HP

7.5 kW

15 HP

11 kW

20 HP

15 kW

30 Hp

22.5 kW

Continuous
current
(RMS)

2 A

4 A

5 A

7 A

15 A

20 A

25 A

35 A

50 A

75 A

Continuous 2
min
HP(200%)

1.5 HP

1.1 kW

3 HP

2.2 kW

4 HP

3 kW

6 HP

4.5 kW

10 HP

7.5 kW

15 HP

11 kW

20 HP

15 kW

30 HP

22 kW

40 HP

30 kW

60 HP

45 kW

Peak 2 sec
HP(300%)

2.25 HP

1.7 kW

4.5 HP

3.4 kW

6 HP

4.5 kW

9 HP

6.7 kW

15 HP

11 kW

22.5 HP

17 kW

30 HP

22 kW

45 HP

34 kW

60 HP

45 kW

90 HP

67 kW

Peak 2 sec
current

5 A

12 A

15 A

21 A

36 A

54 A

75 A

100 A

150 A

200 A

PWM dead
time

2.3 s(PMAC2default)

PMAC2 programmable

Output Specifications for 380/460 VAC Amplifier

Up to four blocks (options) can be selected in any power combination.

The total power cannot exceed 35 Hp.

Note:

When 30HP is selected, only two additional axes may be used (three total instead
of four).

Opt 15

Opt 16

Opt 17

Opt 18

Opt 19

Opt 20

Continuous HP
(100 %)

2 HP

3 HP

5 HP

10 HP

20 HP

30 HP

Continuous current
(RMS)

2.5 A

3.5 A

6 A

12.5 A

25 A

35 A

Continuous 2 min
HP (200%)

4 HP

3 kW

6 HP

4.5 kW

10 HP

7.5 kW

20 HP

15 kW

40 HP

30 kW

60 HP

45 kW

Peak 2 sec HP
(300%)

6 HP

4.5 kW

9 HP

6.7 kW

15 HP

11 kW

30 HP

22 kW

60 HP

45 kW

90 HP

67 kW

Peak 2 sec current

7.5 A

10.5 A

18 A

40 A

75 A

100 A

PWM

dead-time

2.3 µs (PMAC2 default)

PMAC2 programmable

Advertising