Quad Amp Hardware Reference Manual

Installation

27

During this tuning process, P2Setup also determines the commutation parameters and commands the

PMAC appropriately.

Power Block Option

Continuous Hp

Continuous

Current (A)

Peak Current

2 Sec (A)

Max ADC Value

208/230 VAC

5 0.75

2 5

6.25

6 1.5

4

11

13.75

7 2

5

15

18.75

8 3

7

21

26.25

9

5 15 36 45

10 7.5

20

54

67.5

11 10 25 75

93.75

12 15

35

100

125

13 20

50

150

187.5

14 30

75

200

250

380/460 VAC

15 2

2.5

7.5

9.375

16 3

3.5

10.5

13.125

17 5

6

18

22.5

18 10

12.5

40

50

19 20 25 75

93.75

20 30

35

100

125

Enter Max ADC value in P2-Setup, step Current Protection. Enter Peak Current and Continuous Current values, if
applicable.

F.A.Q

1. PWM Frequency – The default value suggested by P2Setup (4.5 kHz) works well for most

applications. If more heat is generated in the motor than the amplifier, using a higher PWM frequency
may assuage this problem.

a. Set up a Lower Voltage Motor with the Quad Amplifier. The following steps should be

followed in P2Setup to ensure that the appropriate voltage is used for the motor while using the
Quad Amplifier:

After PWM frequency and Phase and Servo frequencies have been set up successfully, click the
Terminal Window tab.

Modify Ix66 using the following formula:

Voltage

_

Bus

_

Amp

_

Quad

voltage

_

peak

_

Motor

*

900

I

66