DR Power Hydraulic 20-Ton User Manual

Page 30

Advertising
background image

26

DR

20-Ton WOOD SPLITTER Safety & Operating Instructions

Figure 23

Removing and Replacing the Hydraulic Fluid and
Filter




















Tools & Supplies Needed:

Rando 46 (Texaco) 4.5 gallons (17L)

Pipe wrench

Screwdriver

Filter element, 198980

1. With the engine stopped, release any

residual hydraulic pressure by moving
the control lever back and forth a
couple of times.

2. Remove the filler plug and then

remove the filter element inside the filler opening (Figure 23).

3. Place a suitable container under the drain elbow of the hydraulic fluid tank (Figure 24).

4. Loosen the pump hose clamp from the pump hose (Figure 24), at the pump end, using

the screwdriver. Then remove the hose from the nipple.

5. While holding the hose up, turn the tank drain elbow 180° counterclockwise using the

pipe wrench and then lower the hose into the fluid container allowing the fluid in the
tank to drain completely (Figure 24).

6. Turn the drain elbow 180° clockwise, reattach the hose to the pump connection nipple

and tighten the clamp.

WARNING! Before performing any maintenance procedure, stop the

engine and disconnect the spark plug wire.

Important! Use only Rando 46 (Texaco) hydraulic fluid or equivalent.

WARNING! Escaping pressurized fluid from hydraulic system leaks can

have enough force to penetrate skin and cause serious injury or death.
Hydraulic fluid can remain highly pressurized while the splitter motor is off.
- Never use your hand or any part of your body to check for hydraulic system
leaks while the system is pressurized.
- Get professional medical help at once if hydraulic oil penetrates anyone's skin.
- Always release residual energy from pressurized hydraulic fluid and allow the
fluid to cool before doing any maintenance or repair work on the log splitter.

Fill Plug

Filter inside filler tube

Advertising