Adjusting the hydraulic control valve – DR Power Hydraulic 20-Ton User Manual

Page 33

Advertising
background image

DR

20-Ton WOOD SPLITTER Safety & Operating Instructions

29

Figure 26

Figure 27

6. Check and adjust the hydraulic fluid to be about 1" from the top of the tank.
7. Start the splitter engine and operate the ram back and forth a couple of times to bleed

any air from the hydraulic system.

8. The pressure gauge should indicate a pressure in the “green” area of the pressure gauge

dial (0-25 psi).

9. Recheck and adjust the hydraulic fluid level per step 6.

Adjusting the Hydraulic Control Valve


Tools Needed
:

7/16" wrench
1/8" (9mm) Hex wrench


If the hydraulic push ram will not return all the way back to it’s retracted position, the
locked position (detent) on the right side (Operator’s side) of the control valve may have to
be adjusted.

1. Pull off the black protective cap (Figure 26) on the right side of the control valve and

loosen the jam nut with the 7/16" wrench (Figure 27).

2. Using the Hex wrench, turn the screw on the control valve clockwise, a quarter turn at

a time (Figure 27), until the push ram will return to it’s fully retracted position. Re-
tighten the jam nut and replace the protective cap.



Protective
Cap

Jam Nut Hex Screw

Advertising